ADA Porta Potty Requirements for California Events
Each bank of units needs at least one accessible unit. We count ADA units bank by bank and plan a firm, level path to every one.
How many ADA units? Five percent of each cluster, and never zero
California's building code answers it in one exception. Under CBC 11B-213.2, Exception 3, where single-user portable toilets are grouped at one location, 5 percent of the units at each cluster, but no fewer than one, have to be accessible. Each accessible unit is marked with the International Symbol of Accessibility, the wheelchair sign, on the outside.
The federal text is worded the other way round. The 2010 ADA Standards say no more than 5 percent of the units at a cluster are required to comply, and the U.S. Access Board's guide reads that as access to at least 5 percent at each cluster. California's code leaves no room for argument: no fewer than one at every cluster, even a bank of two.
The ADA unit is one of the units in the cluster, not an extra on top. If the guest count puts you at nine units in one spot, one of those nine is the ADA unit. The porta potty calculator gets you the nine.
Worked counts: the 5 percent always rounds up
Both the federal standards and the California code (section 11B-104.2) say that when a percentage leaves a fraction, you go to the next whole number. A cluster of 21 units is 1.05 at 5 percent, so it needs two ADA units, not one.
The table is arithmetic on that rule, one cluster at a time.
| Units in the cluster | 5 percent | ADA units required |
|---|---|---|
| 2 | 0.1 | 1 |
| 6 | 0.3 | 1 |
| 20 | 1.0 | 1 |
| 21 | 1.05 | 2 |
| 40 | 2.0 | 2 |
| 45 | 2.25 | 3 |
Same twelve units, two layouts
One bank of 12 near the entrance: 5 percent is 0.6, so one ADA unit.
Eight by the main stage and four by the food trucks: two clusters, each needing its own, so two ADA units.
Three banks of four along a race course: three clusters, three ADA units.
Splitting the units across the site? Each spot gets counted on its own
The rule runs per cluster. Your layout changes the ADA count as much as the headcount does. A street fair that spreads its units along four blocks so nobody walks far ends up with more ADA units than one that puts every unit in one bank.
Neither layout is wrong. Spread-out banks mean shorter lines and shorter walks. One bank means fewer ADA units and one service stop for the truck. When you call, tell us where you'd like units to go, and we'll give you the ADA count for each layout before you settle on one.
Can a wheelchair get to the unit? The route has to be firm, wide and close to flat
An ADA unit at the far end of a soft lawn doesn't do its job. The 2010 standards set the basics for the path from the event to the door:
- Surface: stable, firm and slip resistant. If a wheel sinks in or skids, the surface fails, so loose gravel and wet grass are the usual trouble spots.
- Width: at least 36 inches clear. It can narrow to 32 inches for a stretch of no more than 24 inches, such as between two barricades.
- Slope: a walking surface can rise no more than 1 in 20. Over 10 feet of path, that's a 6 inch rise at most.
- Ramps: anything steeper is a ramp, and a ramp can be no steeper than 1 in 12, or 10 inches of rise over the same 10 feet.
- Turning space: a 60 inch circle so a wheelchair can turn. The ADA unit rental page covers what that means for the unit and the pad it stands on.
The unit itself goes on level ground. Put it at the end of the bank nearest the route, with the door facing the path. Nobody should have to roll around the back of the bank to get in.
Jobsite, not an event? The construction exemption is narrow
Section 203.2 of the 2010 standards exempts portable toilets used only by construction workers on a construction site. Those units don't fall under the 5 percent rule, and they don't have to sit on an accessible route.
The key word is only. A sales office open to buyers, a site open house or a unit shared with a neighboring event isn't used exclusively by the crew any more, and the exemption stops fitting. Say on the call who will use the units, and the count follows from that. The crew count itself is on the construction rental page.
Useful to have when you call
- A rough site map, or a list of where people gather
- How many units you want at each spot
- The ground at each spot: pavement, lawn, gravel or sand
- Anything between the crowd and the units, like curbs, steps or cable runs
Know where the restroom banks will go?
Walk us through the spots on the call and how many units each one gets. We'll work out the ADA unit count per cluster and where each one stands.
No obligation to call.